docs: fix markup in Axis_Twist_Compensation.md (#6827)
Browse files Browse the repository at this point in the history
Signed-off-by: Thijs Triemstra <[email protected]>
  • Loading branch information
thijstriemstra authored Mar 1, 2025
1 parent 941fb5a commit 730e595
Showing 1 changed file with 12 additions and 12 deletions.
24 changes: 12 additions & 12 deletions docs/Axis_Twist_Compensation.md
Original file line number Diff line number Diff line change
@@ -1,6 +1,6 @@
# Axis Twist Compensation

This document describes the [axis_twist_compensation] module.
This document describes the `[axis_twist_compensation]` module.

Some printers may have a small twist in their X rail which can skew the results
of a probe attached to the X carriage.
Expand All @@ -25,31 +25,31 @@ try to probe the bed without attaching the probe if you use it.
> correctly set as they greatly influence calibration.
### Basic Usage: X-Axis Calibration
1. After setting up the ```[axis_twist_compensation]``` module, run:
1. After setting up the `[axis_twist_compensation]` module, run:
```
AXIS_TWIST_COMPENSATION_CALIBRATE
```
This command will calibrate the X-axis by default.
- The calibration wizard will prompt you to measure the probe Z offset at
- The calibration wizard will prompt you to measure the probe Z offset at
several points along the bed.
- By default, the calibration uses 3 points, but you can specify a different
- By default, the calibration uses 3 points, but you can specify a different
number with the option:
``
SAMPLE_COUNT=<value>
``

2. **Adjust Your Z Offset:**
After completing the calibration, be sure to [adjust your Z offset]
(Probe_Calibrate.md#calibrating-probe-z-offset).
After completing the calibration, be sure to
[adjust your Z offset](Probe_Calibrate.md#calibrating-probe-z-offset).

3. **Perform Bed Leveling Operations:**
Use probe-based operations as needed, such as:
- [Screws Tilt Adjust](G-Codes.md#screws_tilt_adjust)
- [Z Tilt Adjust](G-Codes.md#z_tilt_adjust)
- [Screws Tilt Adjust](G-Codes.md#screws_tilt_adjust)
- [Z Tilt Adjust](G-Codes.md#z_tilt_adjust)

4. **Finalize the Setup:**
- Home all axes, and perform a [Bed Mesh](Bed_Mesh.md) if necessary.
- Run a test print, followed by any
- Home all axes, and perform a [Bed Mesh](Bed_Mesh.md) if necessary.
- Run a test print, followed by any
[fine-tuning](Axis_Twist_Compensation.md#fine-tuning)
if needed.

Expand All @@ -75,8 +75,8 @@ In this mode, the calibration process will run for both axes automatically.
## [axis_twist_compensation] setup and commands

Configuration options for [axis_twist_compensation] can be found in the
Configuration options for `[axis_twist_compensation]` can be found in the
[Configuration Reference](Config_Reference.md#axis_twist_compensation).

Commands for [axis_twist_compensation] can be found in the
Commands for `[axis_twist_compensation]` can be found in the
[G-Codes Reference](G-Codes.md#axis_twist_compensation)