Fix bandwidth will be set to 0000 in sx127X_setLoRaCR() ; Add many ioctl #16
Add this suggestion to a batch that can be applied as a single commit.
This suggestion is invalid because no changes were made to the code.
Suggestions cannot be applied while the pull request is closed.
Suggestions cannot be applied while viewing a subset of changes.
Only one suggestion per line can be applied in a batch.
Add this suggestion to a batch that can be applied as a single commit.
Applying suggestions on deleted lines is not supported.
You must change the existing code in this line in order to create a valid suggestion.
Outdated suggestions cannot be applied.
This suggestion has been applied or marked resolved.
Suggestions cannot be applied from pending reviews.
Suggestions cannot be applied on multi-line comments.
Suggestions cannot be applied while the pull request is queued to merge.
Suggestion cannot be applied right now. Please check back later.
Fix bandwidth will be set to 0000 in sx127X_setLoRaCR() ;
Add many ioctl ops;
Set LowFrequencyModeOn of SX127X_REG_OP_MODE when sx127X_setLoRaFreq();
With these change, I can control our LoRa stm8 node with this LoRa linux arm board finally.